An automated garage door is something we tend to take for granted. We rely on our door openers to help us get safely in and out when it rains, to protect our cars and homes and to provide an added level of convenience in our day-to-day lives.
Chamberlain's Universal Garage Door Opener Remote Control is designed to work with all major garage door opener brands and can be programmed to operate up to two different branded garage door openers from the same remote. This means no more fumbling around to find the right garage door remote in the morning rush, or in the dark.
The good news is programming the remote can take less than a minute! Here are some instructions that will help you program most garage door openers. If you have an ATA garage door opener, refer to the remote's unique instruction manual.
It's a good idea to read through all steps before commencing and ensure you're familiar with the control buttons. Once you've started programming, it's important to continue to the next step reasonably quickly
Instructions
Operating as a subsidiary of the Chamberlain Group, Liftmaster is a popular manufacturer of automatic garage door openers and gate operators for residential and commercial customers. Liftmaster Elite series gate operators are controlled by Chamberlain-Liftmaster Security Plus remote controls. Get the LiftMaster garage door support you need from Chamberlain Group. Whether you have a belt drive, chain drive or wall-mount model, find helpful resources – manuals, videos and more – to help you diagnose and fix the problem. . Garage door opener: Located on the same side the antenna hangs from, you may have to remove the light lens. The Learn button may be green, orange, red, purple, or yellow with a small LED next to it. ELITE Series Garage Door Opener The Chamberlain Group, Inc. Door if you hold the button on the door control or keyless entry until the.
1. Locate the learn button on your garage door opener. It could also be labelled CODE, CODE SET, DOOR CODE, RADIO SET, ‘S', or something similar.
2. Ensure your garage door is closed and free of obstructions.
3. Press and hold the bottom button on the remote control until the blue LED light stays on solid (this will take approximately 15 seconds), then release the button (the blue LED light will stay on for 60 seconds).
4. Press the learn button on your garage door opener for 2-3 seconds, then release it.
5. Immediately press and release the button on the remote control you would like to program.
6. The blue LED light will commence blinking for 12 seconds. Once the blue LED light changes to a solid slight, immediately press and release the button on the remote control that you are programming.
7. The blue LED light on the remote control will begin to flash once every three seconds. Wait until the door begins moving again and immediately (within three seconds) press the remote button again (depending on the opener brand, this could take a little while).
8. The process is complete and the remote should now be programmed to the garage door opener. You can repeat this process using the other button on the remote to program another garage door opener, if required.
9. Test the remote control by pressing the button you programmed to control the garage door. If the garage door opener doesn't activate, repeat the programming steps, view the programming videos or contact
Chamberlain Customer service on 0800 653 667.
Elite Gate Operators
For more information, clickhere to watch our How to program your Universal remote video.
Tips if you're programming two doors
Chamberlain Elite Gate Opener Learn Button Location Access Master
If you're programming two doors in the same location, we recommend setting up the top button on the remote first. This will also help to ensure you avoid accidentally opening a pre-programmed door.
The bottom button on the remote is the programming button and is the only button that can commence the programming sequence – irrespective of which button you choose to control the door. This button requires a firm press, eliminating accidental activation due to mishandling the remote.
If you have any other questions or need support with your products, contact Chamberlain Customer Service on 0800 653 667
It is common knowledge that Elite gate opener repair can be done by the homeowner himself. However, if it is one of your first attempts to deal with such a device, you may feel not confident enough to tackle the problem. The tables below provide you with information on the most common malfunctions, and you are free to choose the solutions that go well with your repair experience.CONDITION | POSSIBLE CAUSES | SOLUTIONS |
OVERLOAD LED ON And POWER LED OFF | 1 .Short circuit at terminals 8 and 10 2.Short circuit at any of the loop detectors in the board 3.Short circuit in the control board | 1.Remove the short circuit condition at the terminals |
2.Remove the defective loop detector 3.Send the board to repair | ||
OVERLOAD LED ON And POWER LED ON | 1 .Excessive current draw at terminal 10 2.Over-voltage at the 120 VAC line input | 1 .Reduce the accessories load from terminal 10 2.Verify your electrical power |
SYSTEM ON LED FLASHING | 1 .One limit switch is faulty 2.Motor thermal fuse has popped-out | 1 .Test the limit switches and wire connections, fix the fault 2.Reset the motor |
REVERSE SENSOR LED ON | 1 .Gate has encountered and obstruction during traveling 2.Reverse sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the reverse sensor switch counter clockwise a little more and try again | ||
ALARM SENSOR LED ON | 1 .Gate encountered an obstruction during traveling 2.Alarm sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the alarm sensor switch counter clockwise a little more and try again | ||
ALARM SENSOR LED ON | 1 .Gate encountered and obstruction during traveling 2.Alarm sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the alarm sensor switch counter clockwise a little more and try again | ||
COMMAND PROCESSED LED ON | 1 .There is a command hold active | 1 .This is a normal response of the gate operator. It does not represent necessarily that there is a problem. |
TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING | 1.There is a command holding the gate open | 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. Check inputs for command. |
TIMER LED BLINKING, COMMAND PROCESSED LED BLINKING And REVERSE SENSOR LED ON | 1 .Gate has reopened because it encountered an obstruction while closing. | 1 .Any renew command will resume normal operation. Check for obstructions. |
AUDIO ALARM ON | 1 .Gate has encountered two consecutive obstructions while trying to close or open | 1.Any renew command will resume normal operation but not a radio command. Check for obstructions. |
2.You can stop the alarm by using the stop button. | ||
ANY-LOOP LED ON And NO VEHICLE ON THE SENSING AREA | 1 .The loop detector needs to be reset. | 1.Reset the loop detector (If you use Elite Plug-in Loop detectors, change the setting for sensitivity and come back to your original setting). |
2.The wire loop has been disrupted | 2.Verify and correct connections | |
3.The loop detector needs to work in a different frequency | 3.Set a different working frequency | |
4.The loop detector is too sensitive | 4.Decrease the sensitivity of the loop detector |
Chamberlain Elite Csw200ul3
Chamberlain's Universal Garage Door Opener Remote Control is designed to work with all major garage door opener brands and can be programmed to operate up to two different branded garage door openers from the same remote. This means no more fumbling around to find the right garage door remote in the morning rush, or in the dark.
The good news is programming the remote can take less than a minute! Here are some instructions that will help you program most garage door openers. If you have an ATA garage door opener, refer to the remote's unique instruction manual.
It's a good idea to read through all steps before commencing and ensure you're familiar with the control buttons. Once you've started programming, it's important to continue to the next step reasonably quickly
Instructions
Operating as a subsidiary of the Chamberlain Group, Liftmaster is a popular manufacturer of automatic garage door openers and gate operators for residential and commercial customers. Liftmaster Elite series gate operators are controlled by Chamberlain-Liftmaster Security Plus remote controls. Get the LiftMaster garage door support you need from Chamberlain Group. Whether you have a belt drive, chain drive or wall-mount model, find helpful resources – manuals, videos and more – to help you diagnose and fix the problem. . Garage door opener: Located on the same side the antenna hangs from, you may have to remove the light lens. The Learn button may be green, orange, red, purple, or yellow with a small LED next to it. ELITE Series Garage Door Opener The Chamberlain Group, Inc. Door if you hold the button on the door control or keyless entry until the.
1. Locate the learn button on your garage door opener. It could also be labelled CODE, CODE SET, DOOR CODE, RADIO SET, ‘S', or something similar.
2. Ensure your garage door is closed and free of obstructions.
3. Press and hold the bottom button on the remote control until the blue LED light stays on solid (this will take approximately 15 seconds), then release the button (the blue LED light will stay on for 60 seconds).
4. Press the learn button on your garage door opener for 2-3 seconds, then release it.
5. Immediately press and release the button on the remote control you would like to program.
6. The blue LED light will commence blinking for 12 seconds. Once the blue LED light changes to a solid slight, immediately press and release the button on the remote control that you are programming.
7. The blue LED light on the remote control will begin to flash once every three seconds. Wait until the door begins moving again and immediately (within three seconds) press the remote button again (depending on the opener brand, this could take a little while).
8. The process is complete and the remote should now be programmed to the garage door opener. You can repeat this process using the other button on the remote to program another garage door opener, if required.
9. Test the remote control by pressing the button you programmed to control the garage door. If the garage door opener doesn't activate, repeat the programming steps, view the programming videos or contact
Chamberlain Customer service on 0800 653 667.
Elite Gate Operators
For more information, clickhere to watch our How to program your Universal remote video.
Tips if you're programming two doors
Chamberlain Elite Gate Opener Learn Button Location Access Master
If you're programming two doors in the same location, we recommend setting up the top button on the remote first. This will also help to ensure you avoid accidentally opening a pre-programmed door.
The bottom button on the remote is the programming button and is the only button that can commence the programming sequence – irrespective of which button you choose to control the door. This button requires a firm press, eliminating accidental activation due to mishandling the remote.
If you have any other questions or need support with your products, contact Chamberlain Customer Service on 0800 653 667
It is common knowledge that Elite gate opener repair can be done by the homeowner himself. However, if it is one of your first attempts to deal with such a device, you may feel not confident enough to tackle the problem. The tables below provide you with information on the most common malfunctions, and you are free to choose the solutions that go well with your repair experience.CONDITION | POSSIBLE CAUSES | SOLUTIONS |
OVERLOAD LED ON And POWER LED OFF | 1 .Short circuit at terminals 8 and 10 2.Short circuit at any of the loop detectors in the board 3.Short circuit in the control board | 1.Remove the short circuit condition at the terminals |
2.Remove the defective loop detector 3.Send the board to repair | ||
OVERLOAD LED ON And POWER LED ON | 1 .Excessive current draw at terminal 10 2.Over-voltage at the 120 VAC line input | 1 .Reduce the accessories load from terminal 10 2.Verify your electrical power |
SYSTEM ON LED FLASHING | 1 .One limit switch is faulty 2.Motor thermal fuse has popped-out | 1 .Test the limit switches and wire connections, fix the fault 2.Reset the motor |
REVERSE SENSOR LED ON | 1 .Gate has encountered and obstruction during traveling 2.Reverse sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the reverse sensor switch counter clockwise a little more and try again | ||
ALARM SENSOR LED ON | 1 .Gate encountered an obstruction during traveling 2.Alarm sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the alarm sensor switch counter clockwise a little more and try again | ||
ALARM SENSOR LED ON | 1 .Gate encountered and obstruction during traveling 2.Alarm sensor is extra sensitive | 1.Remove the obstruction |
2.Turn the alarm sensor switch counter clockwise a little more and try again | ||
COMMAND PROCESSED LED ON | 1 .There is a command hold active | 1 .This is a normal response of the gate operator. It does not represent necessarily that there is a problem. |
TIMER LED BLINKING And COMMAND PROCESSED LED BLINKING | 1.There is a command holding the gate open | 1. This is a normal response of the gate operator. It does not represent necessarily that there is a problem. Check inputs for command. |
TIMER LED BLINKING, COMMAND PROCESSED LED BLINKING And REVERSE SENSOR LED ON | 1 .Gate has reopened because it encountered an obstruction while closing. | 1 .Any renew command will resume normal operation. Check for obstructions. |
AUDIO ALARM ON | 1 .Gate has encountered two consecutive obstructions while trying to close or open | 1.Any renew command will resume normal operation but not a radio command. Check for obstructions. |
2.You can stop the alarm by using the stop button. | ||
ANY-LOOP LED ON And NO VEHICLE ON THE SENSING AREA | 1 .The loop detector needs to be reset. | 1.Reset the loop detector (If you use Elite Plug-in Loop detectors, change the setting for sensitivity and come back to your original setting). |
2.The wire loop has been disrupted | 2.Verify and correct connections | |
3.The loop detector needs to work in a different frequency | 3.Set a different working frequency | |
4.The loop detector is too sensitive | 4.Decrease the sensitivity of the loop detector |